R-448A · Medium Temperature (Cooler)

6 HP walk-in cooler refrigeration system

6 current R-448A condensing units at 6 HP, rated 35,080–47,250 BTU/h at 95°F ambient, with the 5 unit coolers matched to that capacity. Sized for a walk-in cooler holding 35°F.

Outdoor remote refrigeration condensing unit of the type supplied with a 6 HP walk-in cooler system
6
Horsepower
47,250
BTU/h at 95°F ambient
6
Condensing units
5
Matched evaporators
6 models

6 HP R-448A condensing units

R-448A is the current refrigerant for this class. R-448A is a non-flammable A1 blend and the direct replacement for R-404A.

6 HP R-448A Medium Temperature (Cooler) condensing units — 6 models
ModelSeriesSiting CompressorBTU/h @ 90°F BTU/h @ 95°FElectrical D × W × HWeight
WBOS06E4SEB Next-Gen II Scroll Indoor / Outdoor Scroll · Non-Flooded 36,340 35,080 208/230/3/60 · 3-ph 49 × 38-5/16 × 36-3/8″ 710 lb
WBOS06E4SGB Next-Gen II Scroll Indoor / Outdoor Scroll · Non-Flooded 36,340 35,080 460/3/60 · 3-ph 49 × 38-5/16 × 36-3/8″ 710 lb
WBO600E4SEB Preassembled Remote Indoor / Outdoor Scroll 48,680 47,250 208-230 · 3-ph 33 × 43.875 × 35″ 405 lb
WFOS06E4SEA Next-Gen II Scroll Outdoor Scroll · Flooded 36,340 35,080 208/230/3/60 · 3-ph 49 × 38-5/16 × 36-3/8″ 710 lb
WFOS06E4SGA Next-Gen II Scroll Outdoor Scroll · Flooded 36,340 35,080 460/3/60 · 3-ph 49 × 38-5/16 × 36-3/8″ 710 lb
WFO600E4SEA Preassembled Remote Outdoor Scroll 48,680 47,250 208-230 · 3-ph 33 × 43.875 × 35″ 405 lb

Ratings are the manufacturer’s published capacities at 25°F suction for the ambient shown. A dash means the figure is not published for that model — call 954-237-6753 and we will confirm it.

5 unit coolers

Evaporators used with this system

These are the R-448A medium-temperature unit coolers used with a 6 HP condensing unit. The evaporator is what decides the room: a low-temperature coil makes it a freezer, a medium-temperature coil makes it a cooler.

R-448A Medium Temperature (Cooler) unit coolers matched to 6 HP — 5 models
ModelSeries BTU/hCFMFans DefrostVoltage L × W × H
WE6A258ADAS Center Mount Ultra Low Profile Unit Cooler 30,400 3,150 5 Air 115 112 × 28.375 × 13.75″
WL6A260ADAS Low Profile Walk-In Unit Cooler 30,400 3,100 4 Air 115 76.625 × 15.5 × 18.125″
WL6A295ADAS Low Profile Walk-In Unit Cooler 36,100 3,875 5 Air 115 93.125 × 15.5 × 18.125″
WL6A330ADAS Low Profile Walk-In Unit Cooler 38,800 4,650 6 Air 115 109.625 × 15.5 × 18.125″
WL6A390ADAS Low Profile Walk-In Unit Cooler 45,900 4,650 6 Air 115 109.625 × 15.5 × 18.125″

Grouped by published capacity against this horsepower class. Note that the two ratings are published at different conditions — the condensing unit at the ambient and suction temperature shown above, the unit cooler at its rated temperature difference — so the BTU figures are not meant to be read against each other one for one. The final evaporator for your job depends on the box size, the door traffic, the product going in and the ambient around it — we do that calculation for you before anything is quoted. Call 954-237-6753.

Need this system sized for your box?

Send us the inside dimensions and what you are storing. You get a drawing and a price, not a runaround.

Get a free quote All refrigeration systems

Condensing units are UL and cUL listed for indoor or outdoor use. Unit coolers are UL and cUL listed, NSF approved for use in food preparation areas, and AWEF certified for walk-in coolers and freezers in boxes under 3,000 sq. ft.